Henan LinkZone Fire Technology Co.,Ltd

The Leader Manufacturer of Automatic Fire Monitor!

Manufacturer from China
Active Member
3 Years
Home / Products / Automatic Fire Monitor /

LinkZone ZDMS Automatic Fire Water Monitor 0.6Mpa 40m Radius Monitoring

Contact Now
Henan LinkZone Fire Technology Co.,Ltd
City:zhengzhou
Country/Region:china
Contact Person:Alex Zhang
Contact Now

LinkZone ZDMS Automatic Fire Water Monitor 0.6Mpa 40m Radius Monitoring

Ask Latest Price
Video Channel
Brand Name :LinkZone
Model Number :ZDMS0.6/5S-LZII
Certification :CCCF
Place of Origin :China
MOQ :1set
Price :Negotiable
Payment Terms :T/T, L/C
Supply Ability :2000sets per month
Delivery Time :5~8 work days
Packaging Details :carton box,32*32*35cm
Product Name :Automatic Fire Monitor
Mode No. :ZDMS0.6/5S-LZII
Working Voltage :DC 36V
Rated Pressure :0.6Mpa
Protection Radius :30m
Rate of flow :5L/s
Installation Height :6~15m
Communication Mode :CAN bus
Monitoring Radius :40m
Applicable voltage :AC 110V~240V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
LinkZone ZDMS Automatic Fire Monitor For Fire Extinguishing
Automatic fire monitor

Quick Detail:

●365days uninterrupted video monitoring.

●360° horizontal rotate and 120° vertical rotate.

●High pressure,quick response ,long jet distance and large protection range.

Infrared thermal imaging detecting technology ensure no miss alarming and no fault alarming.

●Applicable voltage range:AC 110V~240V.

●Multifunctions:Fire monitoring,Fire alarming and Fire extinguishing.

●Water saving.

Remote control and automatically scanning.

Specifications:

ZDMS0.6/5S-LZII ZDMS0.6/10S-LZII ZDMS0.8/20S-LZII ZDMS0.9/30S-LZII ZDMS0.8/40S-LZII ZDMS0.8/50S-LZII ZDMS1.0/60S-LZII
Working Voltage DC36V DC36V DC24V DC24V DC24V DC24V DC24V
Rated Pressure 0.6MPa 0.6MPa 0.8MPa 0.9MPa 0.8MPa 0.8MPa 1.0MPa
Protection Radius ≤30m 35m 50m 55m 60m 65m 70m
Rate of flow 5L/s 10L/s 20L/s 30L/s 40L/s 50L/s 60L/s
Installation Height 6~15m 6~15m 8~35m 8~35m 8~35m 8~35m 8~35m
Jet radius 34m 39m 56m 62m 67m 73m 78m
Positioning time ≤30s ≤30s ≤60s ≤60s ≤60s ≤60s ≤60s
Monitoring radius 40m 40m 60m 60m 80m 80m 80m
Flange Connection DN50 DN50 DN80 DN80 DN100 DN100 DN100

Notices:

1.The side of cannon with label”this side to wall” must be faced to wall when installed.
2.Video line connected from DVR to cannon directly.
3.Signal lines must connect to signal lines of cannon where it is 2m from cannon.
4.Operation panel installed near the exit and 1.5m from ground,and from where operator can see all cannnons controlled by this operation panel.
5.Pls take care when handling cannon as there is UV detector at the bottom of cannon.The UV detetor is fragile.
6.Make sure there is no barrier around the cannon to stop the cannon 360 degree rotate.
7.The ground lead of DVR,earth wire and Lightning protection wire of control console need be connected to your ground lead.

Description:

Our automatic fire monitor system discharge large volumes of suppression agent from a single fixed location, and at high pressure to give it an excellent range of coverage.The automatic fire water monitor has built-in infrared thermal imaging detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector. The automatic fire water monitor works with the external UV flame detector to eliminate the detection blind area and increase early warning range.
When the automatic fire water monitor receives the fire early warning signal (UV or IR signal), the water monitor built-in image IR flame detector will automatically rotate along with the water monitor and lock the flame for 3 seconds, then spray to extinguish the fire. Otherwise, the water monitor will be considered as a false alarm, and the water monitor will reset automatically.The time spent from fire started to fire targeted is less than 30 seconds.

LinkZone ZDMS Automatic Fire Water Monitor 0.6Mpa 40m Radius Monitoring

Applications:

Our automatic fire monitor are wildly used in Industrial,commercial and residential fields.Such as airport, high-speed railway station, bus station, hotel atrium, museum, library, TV studio, gymnasium, science and technology museum, exhibition hall, convention center, theater, cinema, civic activity center, industrial plant, chemical plant, gas station, oil port,helicopter hangar, power plants, logistics centers, hospitals, large shopping malls, commercial complexes, colleges and universities, coal mines, warehouses and other places with large space.

LinkZone ZDMS Automatic Fire Water Monitor 0.6Mpa 40m Radius Monitoring

FAQ:

Q1: Are you a manufacturer?

A1: Yes. We are a professional and No.1 manufacture of automatic fire water monitor which has the most advanced technology.
Q2: What certificates do you have?
A2: We only have CCCF and ISO certificate at present. And we plan to do FM certificate later.
Q3: What are the advantages of your Automatic Fire Monitor?
A3: Our Automatic Fire Monitor adopt the Infrared thermal imaging detecting and targeting technology. Our Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Intelligent Fire Extinguishing.

Inquiry Cart 0